Installation, Operation and Maintainance of Automatic Meteorological Stations
;============= CONTINUE WITH DAILY OUTPUT ===================
58: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 1440 Interval (same units as above)
3: 10 Set Output Flag High
59: Set Active Storage Area (P80)
1: 1 Final Storage Area 1
2: 100 Array ID
60: Signature (P19)
1: 22 Loc [ SIGN1440 ]
;CREATE DAILY PROGRAM SIGNATURE TO MONITOR ADEQUATE PROGRAM PERFORMANCE
61: Sample (P70)
1: 1 Reps
2: 24 Loc [ LOGGER_ID ]
62: Real Time (P77)
1: 1200 Year,Day (midnight = 2400)
63: Average (P71)
1: 1 Reps
2: 1 Loc [ AIR_TEMP ]
64: Average (P71)
1: 1 Reps
2: 8 Loc [ VP ]
65: Average (P71)
1: 1 Reps
2: 10 Loc [ VPD ]
66: Maximize (P73)
1: 1 Reps
2: 10 Value with Hr-Min
3: 1 Loc [ AIR_TEMP ]
67: Minimize (P74)
1: 1 Reps
2: 10 Value with Hr-Min
3: 1 Loc [ AIR_TEMP ]
68: Totalize (P72)
1: 1 Reps
2: 6 Loc [ RAIN ]
69: Sample (P70)
1: 1 Reps
2: 15 Loc [ OD_SOLAR ]