Appendix F. CR510PB w/ P193 Master to CR205s Network
F-6
from SE1 to
and the 10K resistor from EX1 to SE1. The result will
be a simulated temperature reading of 22°C ± 2 degrees.
2. Configure a CR510PB PakBus address of “100” in Edlog’s
Options\Pakbus Settings:
FIGURE F-2. P193 Edlog PakBus Settings
The maximum nodes, maximum neighbors, and maximum routers entries
allow the CR510PB to function as a router in the network.
Notice that “Network” is the only setup group unchecked. There is no need
of Neighbor Filter or Beacon setup because the P193 creates a static route
to each CR205 in the swath.
3. Save and compile the program as P193TRANSFER.dld
4. Send the program to the CR510PB
5. Configure a Numeric Display in Connect Screen showing the CR510PB’s
Input Locations to monitor the remote CR205s’ variables. You can click
and drag to organize the display Input Locs to look something like this.