Met One 034B Windset
08: Wind Vector (P69)
1: 1 Reps
2: 0 Samples per Sub-Interval
3: 00 S, θu, & σ(θu) Polar***
4: 1* Wind Speed [ WndS_m_s ]
5: 2* Wind Direction [ WndD_deg ]
-Input Locations-
1 WndS_m_s
2 WndD_deg
* Proper entries will vary with program and datalogger channel and input location assignments.
** On the 21X use the 5000 mV input range and the a 5000 mV excitation voltage.
*** Average wind speed, average unit vector wind direction, standard deviation of unit vector wind
direction
6. Sensor Maintenance
1 Month
Do a visual/audio inspection of the anemometer at low wind speeds.
Verify that the cup assembly and wind vane rotate freely. Inspect the
sensor for physical damage. Verify cups and vane are tight.
6 Months
Replace anemometer bearings if operating under harsh conditions
1 Year
Replace anemometer bearings. Contact Campbell Scientific for a Return
Materials Authorization (RMA) number at (801) 753-2342.
2 Years
Replace the wind vane potentiometer and bearings. Contact Campbell
Scientific for a Return Materials Authorization (RMA) number at (801)
753-2342.
7. Troubleshooting
7.1 Wind Direction
Symptom: -9999 or no change in direction
1. Check that the sensor is wired to the Excitation and Single-Ended channel
specified by the measurement instruction.
2. Verify that the excitation voltage and Range code are correct for the
datalogger type.
3. Disconnect the sensor from the datalogger and use an ohm meter to check
the potentiometer. Resistance should be vary from 11K to 21K ohms
between the blue and green wires depending on vane position. Resistance
should be vary from 1K to 11K ohms between the white and green wires
depending on vane position.
11