Page 1 - AM25T Solid State Multiplexer

AM25T Solid State MultiplexerRevision: 1/10Copyright © 1995-2010Campbell Scientific, Inc.

Page 2 - Warranty and Assistance

AM25T Solid State Multiplexer AM25T FIGURE 2. External Battery Connections 4. Sensor to AM25T Wiring This section and the examples describe differen

Page 3 - Table of Contents

AM25T Solid State Multiplexer FIGURE 3. Differential Measurement of Type T Thermocouple 4.2 Differential Analog Measurements Connect one differenti

Page 4 - Program Examples

AM25T Solid State Multiplexer 5. General Measurement Considerations Cables have additional capacitance that increases the time required for a signal

Page 5 - 1. General

AM25T Solid State Multiplexer is greater than 1, the Dest parameter must be a variable array. If 0 is entered, the only measurement that is made is th

Page 6 - 1.2 Physical Description

AM25T Solid State Multiplexer ClkPort: The ClkPort argument is the control port that will be used to clock the AM25T. One clock port may be used with

Page 7 - 1.3 Operation

AM25T Solid State Multiplexer Mult, Offset: The Mult and Offset parameters are each a constant, variable, array, or expression by which to scale the r

Page 8 - 2. Installation

AM25T Solid State Multiplexer ‘Main Program BeginProg Scan (1,Sec,0,0) AM25T (TC(),25,mV2_5C,1,1,TypeT,Tref,5,4,Vx1,True,0,250,1.0,0) CallTable D

Page 9

AM25T Solid State Multiplexer 'Only the Reference Temperature is measured and stored in RTemp_C. 'To do this, enter 0 for the REP

Page 10 - 4. Sensor to AM25T Wiring

AM25T Solid State Multiplexer TABLE 6-3. RTD Excitation Voltage and Measurement Range for AM25T Multiplexers Prior to Serial Number 1839 Datalogger

Page 11 - 4.3 Mixed Sensor Types

AM25T Solid State Multiplexer 03: Full Bridge (P6) ;Measure the output of the reference temp. full bridge 1: 1 Reps 2: 23 25 mV 60 Hz Rejec

Page 12 - Datalogger

Warranty and Assistance The AM25T SOLID STATE MULTIPLEXER is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materials and workmansh

Page 13

AM25T Solid State Multiplexer Example 4. CR10(X) Program for Measuring 25 Type T Thermocouples with the Differential Thermocouple Instruction and Lon

Page 14

AM25T Solid State Multiplexer 09: BR Transform Rf[X/(1-X)] (P59) ;Calculate RTD resistance R/R0 1: 1 Reps 2: 1 Loc [ RefTemp_C ] 3: 10.025

Page 15

AM25T Solid State Multiplexer 6.2.2 Example CR23X Program The CR23X uses Instruction 134 for measuring thermocouples or voltages with the AM25T. Exa

Page 16

Appendix A. Single-Ended Measurements Single-ended measurements with the AM25T are not recommended. This is not due to any problem with the AM25T.

Page 17 - 6.2 Edlog Programming

Appendix A. Single-Ended Measurements A.1.1 Thermocouple Measurements Wire the high side of each thermocouple into an input terminal. The low side

Page 18

Appendix A. Single-Ended Measurements 05: Temperature RTD (P16) ;Calculate reference temperature 1: 1 Reps 2: 1 R/R0 Loc [ RefTemp_C ] 3

Page 19

Appendix A. Single-Ended Measurements 03: BR Transform Rf[X/(1-X)] (P59) ;Calculate RTD resistance R/R0 1: 1 Reps 2: 1 Loc [ RefTemp_C ]

Page 20

Appendix A. Single-Ended Measurements FIGURE A-2. Single-Ended Measurement A.2 Indexing with Loops When a multiplexer is measured with a measureme

Page 21

Appendix A. Single-Ended Measurements instruction has one repetition. If the instruction has two repetitions, then every other Input Location will b

Page 22 - 6.2.2 Example CR23X Program

Appendix A. Single-Ended Measurements Example A-4. Measuring Single Ended Thermocouples with the Input Location Indexed and no Step Loop Index 01:

Page 23 - Measurements

AM25T Solid State Multiplexer Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Ac

Page 24

Appendix A. Single-Ended Measurements A-8

Page 25

Appendix B. Differences Between the AM25T, AM416, and the AM32 The AM25T differs from Campbell Scientific's AM416 and AM32 multiplexers in the f

Page 26

Appendix B. Differences Between the AM25T, AM416, and the AM32 B-2

Page 28

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Page 29

AM25T Solid State Multiplexer Table of Contents ii Figures 1. AM25T Thermocouple Multiplexer...

Page 30

AM25T Solid State Multiplexer 1. General The AM25T Multiplexer increases the number of channels for measuring thermocouples or voltage sensors with C

Page 31 - AM25T, AM416, and the AM32

AM25T Solid State Multiplexer OPERATING TEMPERATURE Standard: -40°C to +85°C RTD accuracy ±0.4°C OPERATING HUMIDITY Noncondensing: 0 to 95% DIMENSIO

Page 32

AM25T Solid State Multiplexer The terminal strips that run the length of the AM25T are for sensor connections. All inputs are protected by spark gaps

Page 33

AM25T Solid State Multiplexer Ground (GND) Each differential input channel has a ground terminal located next to it. The ground terminal is common wi

Page 34

AM25T Solid State Multiplexer U-bolts are used to attach the enclosures to a 1.25" NPT pipe. The enclosure may also be lag-bolted to a wall or s