Campbell CS525 Spécifications

Naviguer en ligne ou télécharger Spécifications pour Mesure, test et contrôle Campbell CS525. Campbell CS525 Specifications [en] Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 18
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
CS525 ISFET pH Probe
Revision: 10/11
Copyright © 2009-2011
Campbell Scientific, Inc.
Vue de la page 0
1 2 3 4 5 6 ... 17 18

Résumé du contenu

Page 1 - CS525 ISFET pH Probe

CS525 ISFET pH ProbeRevision: 10/11Copyright © 2009-2011Campbell Scientific, Inc.

Page 2 - WARRANTY AND ASSISTANCE

CS525 ISFET pH Probe TABLE 3-2. CR200(X) Series Wiring Wire Color Wire Label/Function VDIV2:1* CR200(X) Series Red Power 5 Vdc EX Black

Page 3 - PLEASE READ FIRST

CS525 ISFET pH Probe ‘CR200(X) Series ‘Declare the variable for the pH measurement Public pHmV ‘Read sensor every 60 seconds BeginProg Scan(60,

Page 4

CS525 ISFET pH Probe Below is an example program for CR800, CR850, CR1000, and CR3000 dataloggers when the sensor has a ±400 mV output (see Note below

Page 5 - CS525 Table of Contents

CS525 ISFET pH Probe The CS525 has no user-serviceable parts. Cable can be damaged by abrasion, rodents, sharp objects, twisting, crimping or crushing

Page 6

CS525 ISFET pH Probe 8 7. Troubleshooting The most common causes for erroneous pH data include: x poor sensor connections to the datalogger x damag

Page 7

Appendix A. Calibration This calibration process uses a 7 pH and 4 pH buffer solution (CSI part number). After downloading the following example pro

Page 8 - 2. Specifications

Appendix A. Calibration A-2 Battery (Batt_volt) VoltSe (pHmV,1,mV5000,1,False,0,_60Hz,1,0) If pH4record = -1 Then pH4mV = pHmV pH4record = 0

Page 10 - 4. Programming

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Page 11

WARRANTY AND ASSISTANCE This equipment is warranted by CAMPBELL SCIENTIFIC (CANADA) CORP. (“CSC”) to be free from defects in materials and wor

Page 12 - 6. Maintenance

PLEASE READ FIRST About this manual Please note that this manual was originally produced by Campbell Scientific Inc. (CSI) primarily for the US market

Page 14 - 7. Troubleshooting

CS525 Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to

Page 16

CS525 ISFET pH Probe The CS525 probe is designed for general pH measurements in aqueous or semi-solid solutions. It provides a 0 to 5 Vdc output that

Page 17

CS525 ISFET pH Probe connected in the correct way to the datalogger. Any other combinations might cause a loss of performance and irreversible damage

Page 18

CS525 ISFET pH Probe 3. Installation and Wiring Campbell Scientific only offered the 0 to 5000 mV output range for CS525 probes ordered before Januar