INSTRUCTION MANUAL
Model HFP01SC Self-Calibrating
Soil Heat Flux Plate
Revision: 3/14
Copyright © 2002- 2014
Campbell Scientific, Inc.
Vue de la page 0
1 2 3 4 5 6 ... 31 32

Résumé du contenu

Page 1 - INSTRUCTION MANUAL

INSTRUCTION MANUAL Model HFP01SC Self-Calibrating Soil Heat Flux Plate Revision: 3/14 Copyright © 2002- 2014 Campbell Scie

Page 2

Model HFP01SC Self-Calibrating Soil Heat Flux Plate The location of the heat flux plates and thermocouples should represent the area of study. If the

Page 3 - Warranty

Model HFP01SC Self-Calibrating Soil Heat Flux Plate TABLE 6-1. Datalogger Connections for a Single-Ended Measurement Description Color CR10X CR

Page 4 - Assistance

Model HFP01SC Self-Calibrating Soil Heat Flux Plate 6.2 Wiring Connections to Campbell Scientific dataloggers are given in FIGURE 6-1, TABLE 6-1, and

Page 5 - Table of Contents

Model HFP01SC Self-Calibrating Soil Heat Flux Plate Heater Resistor Signal #1 Yellow 13H Heater Resistor Signal Reference #1 Purple Shield #1 Cle

Page 6

Model HFP01SC Self-Calibrating Soil Heat Flux Plate BeginProg 'HFP01SC factory calibration in W/(m^2 mV) = 1000/sensitivity. shf_cal(1) = HFP

Page 7 - Model HFP01SC

Model HFP01SC Self-Calibrating Soil Heat Flux Plate 6.3.2 Example 2. Sample CR10(X) Program Using a Single-Ended Measurement Instruction TABLE 6-4 p

Page 8 - 5. Specifications

Model HFP01SC Self-Calibrating Soil Heat Flux Plate ;Factory calibration in W/(m^2 mV) = 1000/sensitivity. ; 4: Z=F (P30) 1: 1 F ; <- Ente

Page 9 - 6. Installation

Model HFP01SC Self-Calibrating Soil Heat Flux Plate *Table 2 Program 02: 0 Execution Interval (seconds) *Table 3 Subroutines ;Calibration rout

Page 10

Model HFP01SC Self-Calibrating Soil Heat Flux Plate ;Stop filtering data. ; 12: If time is (P92) 1: 39 Minutes (Seconds --) into a 2: 180

Page 11

Model HFP01SC Self-Calibrating Soil Heat Flux Plate 6.3.3 Example 3. Sample CR23X Program Using a Differential Measurement Instruction TABLE 6-5 pro

Page 13

Model HFP01SC Self-Calibrating Soil Heat Flux Plate ;Factory calibration in W/(m^2 mV) = 1000/sensitivity. ; 4: Z=F (P30) 1: 1 F ; <- Ente

Page 14

Model HFP01SC Self-Calibrating Soil Heat Flux Plate *Table 2 Program 02: 0 Execution Interval (seconds) *Table 3 Subroutines ;Calibration rout

Page 15 - Measurement Instruction

Model HFP01SC Self-Calibrating Soil Heat Flux Plate 13: Do (P86) 1: 218 Set Flag 18 Low ;Compute in-situ calibration. ; 14: Z=X (P31) 1:

Page 16

Model HFP01SC Self-Calibrating Soil Heat Flux Plate 6.3.4 Example 4. Sample CR10X Program Using External Power and Relay TABLE 6-6 provides the sens

Page 17

Model HFP01SC Self-Calibrating Soil Heat Flux Plate ;{CR10X} ; *Table 1 Program 01: 1 Execution Interval (seconds) ;Measure HFP01SC on smalles

Page 18

Model HFP01SC Self-Calibrating Soil Heat Flux Plate 11: Beginning of Loop (P87) 1: 0 Delay 2: 6 Loop Count ;Use data from the larger mea

Page 19

Model HFP01SC Self-Calibrating Soil Heat Flux Plate *Table 3 Subroutines ;Calibration routine. ; 1: Beginning of Subroutine (P85) 1: 8 Subrout

Page 20

Model HFP01SC Self-Calibrating Soil Heat Flux Plate 15: End (P95) ;Compute in-situ calibration. ; 16: If time is (P92) 1: 39 Minutes (Second

Page 21

Model HFP01SC Self-Calibrating Soil Heat Flux Plate 5 shf_5 0 0 0 6 shf_6 0 0 0 7 shf_mV_1 1 5 2 8 shf_mV_2 1 0 1 9 shf_mV_3 1 0 1 10 shf_m

Page 22

Model HFP01SC Self-Calibrating Soil Heat Flux Plate θρρθmwbv= (2) where CS is the heat capacity of moist soil, ρb is the bulk density, ρw is the dens

Page 23

Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materi

Page 24

Model HFP01SC Self-Calibrating Soil Heat Flux Plate TABLE 6-8. Hukseflux and Campbell Scientific Variable Names Description Hukseflux Campbell Sci

Page 26

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Page 27

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Page 28 - = + = +ρ θ ρ θ ρ

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec

Page 29

Table of Contents ii

Page 30 - 8. References

Model HFP01SC Self-Calibrating Soil Heat Flux Plate 1. Introduction The HFP01SC Self-Calibrating Heat Flux Sensor measures soil heat flux, typicall

Page 31

Model HFP01SC Self-Calibrating Soil Heat Flux Plate In order to measure soil heat flux at the surface, several HFP01SCs are used to measure the soil h

Page 32

Model HFP01SC Self-Calibrating Soil Heat Flux Plate Sensor: Thermopile and film heater Heater Voltage Input: 9 to 15 Vdc Heater Voltage Output: 0 t