Campbell TDR Manuel

Naviguer en ligne ou télécharger Manuel pour Mesure, test et contrôle Campbell TDR. Campbell TDR Product manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 28
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
TDR Probes CS605, CS610,
CS630, CS635, CS640, CS645
Revision: 9/13
Copyright © 2006-2013
Campbell Scientific, Inc.
Vue de la page 0
1 2 3 4 5 6 ... 27 28

Résumé du contenu

Page 1 - CS630, CS635, CS640, CS645

TDR Probes CS605, CS610, CS630, CS635, CS640, CS645Revision: 9/13 Copyright © 2006-2013Campbell Scientific, Inc.

Page 2

TDR Probes CS605, CS610, CS630, CS635, CS640, CS645 Calculation, with all cabling from TDR100 to probe in place will compensate for the cable losses.

Page 3 - Warranty

TDR Probes CS605, CS610, CS630, CS635, CS640, CS645 datalogger algorithm to analyze the waveform are shifted by the cable losses resulting in error.

Page 4 - Assistance

TDR Probes CS605, CS610, CS630, CS635, CS640, CS645 can affect the accuracy and resolution of water content measurements. FIGURE 7-2 presents a serie

Page 5 - Table of Contents

TDR Probes CS605, CS610, CS630, CS635, CS640, CS645 The combined effect of long cable runs and high soil electrical conductivity must be considered wh

Page 6 - Figures

TDR Probes CS605, CS610, CS630, CS635, CS640, CS645 8

Page 7 - CS635, CS640, CS645

Appendix A. Discussion of TDR Probe Offset and a Simple Laboratory Method for Calculation A.1 Discussion of Probe Offset Probe offset accounts for

Page 8 - 5. Specifications

Appendix A. Discussion of TDR Probe Offset and a Simple Laboratory Method for Calculation A.2 The Compounding Effect of Signal Attenuation in Connec

Page 9 - 7. Operation

Appendix A. Discussion of TDR Probe Offset and a Simple Laboratory Method for Calculation A.3 Method for Calculating Probe Offset Using Information

Page 10

Appendix A. Discussion of TDR Probe Offset and a Simple Laboratory Method for Calculation 4. Enter Terminal Mode using Options/Terminal Emulator. 5.

Page 11 - Conductivity

Appendix A. Discussion of TDR Probe Offset and a Simple Laboratory Method for Calculation thWindowLeng•1datapointsend:endindexdistance−= 65.0startdi

Page 13 - 8. References

Appendix A. Discussion of TDR Probe Offset and a Simple Laboratory Method for Calculation A-6 TABLE A-1. Dielectric permittivity values for range of

Page 14

Appendix B. Correcting Electrical Conductivity Measurements for System Losses TDR system cabling and multiplexers introduce losses of the applied an

Page 15

Appendix B. Correcting Electrical Conductivity Measurements for System Losses electrical conductivity. Kp is calculated as the ratio of electrical c

Page 16 - Connecting Cables

Appendix B. Correcting Electrical Conductivity Measurements for System Losses The temperature effect is described by: ()()25T•02.01•ECEC25T−+= [B4]

Page 17 - () () () ()

Appendix B. Correcting Electrical Conductivity Measurements for System Losses B.2.4 CR1000 Program for Collecting ρopen and ρshorted Values 'Th

Page 18

Appendix B. Correcting Electrical Conductivity Measurements for System Losses 'setting SDMports high will configure control ports 1 thru 3 to al

Page 19

Appendix B. Correcting Electrical Conductivity Measurements for System Losses B-6

Page 21 - B.1 Description of Method

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Page 22 - B.2.2 Determining K

Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materi

Page 23 - ºC and is the electrical

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Page 24 - Values

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec

Page 25

Table of Contents ii B. Correcting Electrical Conductivity Measurements for System Losses...B-1 B.1 Description of Method...

Page 26

TDR Probes CS605, CS610, CS630, CS635, CS640, CS645 1. Introduction This document presents descriptions and instructions for Campbell Scientific Tim

Page 27

TDR Probes CS605, CS610, CS630, CS635, CS640, CS645 as a change in probe impedance which affects the shape of the reflection. The shape of the reflec

Page 28

TDR Probes CS605, CS610, CS630, CS635, CS640, CS645 5.3 Electromagnetic Compatibility All TDR probes are compliant with performance criteria availa

Commentaires sur ces manuels

Pas de commentaire