Appendix B. Alternate Base Station Configurations
B-3
Phone to RF: Each datalogger field site needs the “Dialed Using RF95 Path:”
set. This is the address set in the RF310M RF Modem.
Phone to RF: When a repeater is used, the “Dialed Using RF95 Path:” includes
the path of the repeater followed by the path of the field site. In this case
CR10X4, address 20 is called through CR10X3, address 15.