Campbell HMP50 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Composants des dispositifs de sécurité Campbell HMP50. Campbell Scientific HMP50 [en] Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 20
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
HMP50 Temperature and
Relative Humidity Probe
Revision: 10/09
Copyright © 1995-2009
Campbell Scientific, Inc.
Vue de la page 0
1 2 3 4 5 6 ... 19 20

Résumé du contenu

Page 1 - Relative Humidity Probe

HMP50 Temperature andRelative Humidity ProbeRevision: 10/09Copyright © 1995-2009Campbell Scientific, Inc.

Page 2 - Warranty and Assistance

HMP50 Temperature and Relative Humidity Probe Black Temperature Signal White Relative Humidity Signal Blue Signal & Power Reference Br

Page 3 - HMP50 Table of Contents

HMP50 Temperature and Relative Humidity Probe The temperature and relative humidity signals from the HMP50 are measured using two single-ended analog

Page 4

HMP50 Temperature and Relative Humidity Probe BeginProg Scan(5,Sec,1,0) 'HMP50 Temperature & Relative Humidity Sensor measurements AirTC a

Page 5 - Humidity Probe

HMP50 Temperature and Relative Humidity Probe 6. Long Lead Lengths Long lead lengths cause errors in the measured temperature and relative humidity.

Page 6 - 2.1 Temperature Sensor

HMP50 Temperature and Relative Humidity Probe When the air temperature increases, so does the saturation vapor pressure. Conversely, a decrease in ai

Page 7 - 3. Installation

HMP50 Temperature and Relative Humidity Probe 'CR1000 Public AirTC Public RH Public VP DataTable(Table1,True,-1) DataInterval(0,60,Min,0) Ave

Page 8

HMP50 Temperature and Relative Humidity Probe ;Limit the maximum value of relative humidity ;to 1 (expressed as a fraction). ; 03: If (X<=>F) (

Page 9

HMP50 Temperature and Relative Humidity Probe Shipping Cap(remove prior to installation)Protective Cap and Filter 9598 RH ChipFIGURE 6. Exploded Vie

Page 10 - Clear Shield

HMP50 Temperature and Relative Humidity Probe 14

Page 12 - 5.2 Example for CR10X

Warranty and Assistance The HMP50 TEMPERATURE AND RELATIVE HUMIDITY PROBE is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materia

Page 13 - 7. Absolute Humidity

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Page 14

HMP50 Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab for

Page 15

HMP50 Table of Contents ii Tables 1. Recommended Lead Lengths... 1 2. Datalogger C

Page 16 - 8. Maintenance

HMP50 Temperature and Relative Humidity Probe 1. General The HMP50 Temperature and Relative Humidity probe contains a Platinum Resistance Temperature

Page 17 - 9. References

HMP50 Temperature and Relative Humidity Probe 2.1 Temperature Sensor Sensor: 1000 Ω PRT, DIN 43760B Temperature Measurement Range: -40°C to +60°C T

Page 18

HMP50 Temperature and Relative Humidity Probe 3. Installation 3.1 Siting Sensors should be located over an open level area at least 9 m (EPA) in dia

Page 19

HMP50 Temperature and Relative Humidity Probe Yellow Shipping Cap (remove before installation) FIGURE 1. HMP50 as Shipped FIGURE 2. HMP50 and 4130

Page 20

HMP50 Temperature and Relative Humidity Probe FIGURE 3. HMP50 and 41303-5A Radiation Shield on a CM202 Crossarm FIGURE 4. HMP50 and 41303-5A Ra

Commentaires sur ces manuels

Pas de commentaire