Campbell SDM-CD16D Guide de l'utilisateur Page 11

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 17
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 10
User Guide
5
Figure 4 Use of Terminal Blocks
5. Address Selection Switches
Each SDM-CD16D can have 1 of 16 addresses. The factory-set address is 00.
Table 2 shows switch position and the corresponding address. Figures 1 and
5 shows the position of the switch. Note that you will have to remove the
mounting bracket to gain access to this switch.
Table 2 Switch Position and Addresses
Switch Setting Base 4 Address
000
101
202
303
410
511
612
713
820
921
A22
B23
C30
D31
E32
F33
Use a screwdriver in appropriate slot
to release spring tension
Strip insulation
and insert wire