Campbell LWS-L Manuel de l'opérateur Page 1

Naviguer en ligne ou télécharger Manuel de l'opérateur pour Stations météorologiques Campbell LWS-L. Campbell LWS-L Operator`s manual [en] Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 52
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
John Deere Field Connect™
*OMPFP15006*
OPERATOR'S MANUAL
John Deere Field Connect™
OMPFP15006 ISSUE J4 (ENGLISH)
CALIFORNIA
Proposition 65 Warning
Diesel engine exhaust and some of its constituents
are known to the State of California to cause cancer,
birth defects, and other reproductive harm.
If this product contains a gasoline engine:
WARNING
The engine exhaust from this product contains
chemicals known to the State of California to cause
cancer, birth defects or other reproductive harm.
The State of California requires the above two warnings.
Additional Proposition 65 Warnings can be found in this manual.
John Deere Ag Management Solutions
PRINTED IN U.S.A.
*DCY*
*ompfp15006*
Vue de la page 0
1 2 3 4 5 6 ... 51 52

Résumé du contenu

Page 1 - *ompfp15006*

John Deere Field Connect™*OMPFP15006*OPERATOR'S MANUALJohn Deere Field Connect™OMPFP15006 ISSUE J4 (ENGLISH)CALIFORNIAProposition 65 WarningDiese

Page 2 - Introduction

SafetyDX,SERV -19-17FEB99-1/1DX,WW,MOUNT -19-12OCT11-1/1Practice Safe MaintenanceUnderstand service procedure before doing work. Keeparea clean and dr

Page 3 - FCC Notifications to User

SafetyDX,WW,RECEIVER -19-24AUG10-1/1BA31779,00004E7 -19-14NOV12-1/1Handle Electronic Components and BracketsSafelyFalling while installing or removing

Page 4

SafetyHC94949,0000462 -19-17DEC13-1/1BA31779,00004E9 -19-17JUL12-1/1RM72004,00001E6 -19-05AUG13-1/1Avoid Buried Utility LinesDigging through gas, elec

Page 5

OverviewBA31779,00006E0 -19-29OCT13-1/1RM72004,00001DA -19-29OCT13-1/1System OverviewTheory of OperationThe John Deere Field Connect™ system allows op

Page 6

ComponentsBA31779,0000361 -19-29OCT13-1/4Continued on next page BA31779,0000361 -19-29OCT13-2/4Required ComponentsSystem is composed of several on-boa

Page 7 - Contents

ComponentsContinued on next page BA31779,0000361 -19-29OCT13-3/4Satellite AntennaNOTE: Without clear view of sky at installation site,GPS accuracy is

Page 8

ComponentsBA31779,0000361 -19-29OCT13-4/4Field Connect™ Soil Moisture ProbeNOTE: Improperly installed soil moisture probe degradessoil moisture data.

Page 9 - Follow Safety Instructions

ComponentsBA31779,0000362 -19-20OCT14-1/1BatteryNOTE: Charge battery before first use.A solar panel is part of Field Connect™ system to keepbattery ch

Page 10 - Practice Safe Maintenance

ConnectorsRM72004,00001EC -19-29OCT13-1/1Antenna ConnectionsNOTE: Cellular (A) and satellite antenna cables (C)have same TNC connector receptacles and

Page 11 - Handling Batteries Safely

ConnectorsBA31779,00006A8 -19-29OCT13-1/1Field Connect™ Gateway PortsNOTE: Record port connection for soil moisture probe andeach environmental sensor

Page 12 - Avoid Buried Utility Lines

IntroductionRM72004,00001ED -19-17SEP13-1/1CZ76372,000071F -19-18JUN14-1/1RM72004,00001DD -19-05SEP13-1/1HC94949,0000255 -19-05MAR13-1/1RM72004,00001D

Page 13 - Overview

ConnectorsBA31779,0000363 -19-21OCT13-1/1Soil Moisture Probe ConnectionNOTE: Do not activate probe before connectingit to gateway.Before installing so

Page 14 - Components

WebsiteRM72004,00001D8 -19-29OCT13-1/1RM72004,00001DB -19-29OCT13-1/1BA31779,00006FA -19-29OCT13-1/1CZ76372,000072A -19-17OCT14-1/1CompatibilityWeb Br

Page 15 - PC14727 —UN—20FEB12

SpecificationsContinued on next page BA31779,000036B -19-20OCT14-1/3Field Connect™ GatewayElectrical•Input Voltage—Range, 9–16 V•Fuse—Protect device w

Page 16 - PC17736 —UN—23SEP13

SpecificationsContinued on next page BA31779,000036B -19-20OCT14-2/3SolidDevice presentBlinkingChannel enabled, no device detectedALG 3 (G)Off Channel

Page 17

SpecificationsBA31779,000036B -19-20OCT14-3/3RM72004,00001E0 -19-06AUG13-1/1Charge ControllerLEDSTATE DESCRIPTIONSolid ChargingBlinkingFull ChargeChar

Page 18 - Connectors

SpecificationsRM72004,00001E5 -19-06AUG13-1/1EC Declaration of ConformityDXCE01 —UN—28APR09Deere & CompanyMoline, Illinois USAThe undersigned here

Page 19 - Field Connect™ Gateway Ports

SpecificationsRM72004,00001E4 -19-06AUG13-1/1EC Declaration of ConformityDXCE01 —UN—28APR09Deere & CompanyMoline, Illinois USAThe undersigned here

Page 20 - PC15537 —UN—16JUL12

SpecificationsRM72004,00001E3 -19-06AUG13-1/1EC Declaration of ConformityDXCE01 —UN—28APR09Deere & CompanyMoline, Illinois USAThe undersigned here

Page 21 - Website Navigation

SpecificationsRM72004,00001E2 -19-06AUG13-1/1EC Declaration of ConformityDXCE01 —UN—28APR09Deere & CompanyMoline, Illinois USAThe undersigned here

Page 22 - Specifications

SpecificationsRM72004,00001E1 -19-06AUG13-1/1EC Declaration of ConformityDXCE01 —UN—28APR09Deere & CompanyMoline, Illinois USAThe undersigned here

Page 23

IntroductionBA31779,00006FB -19-29OCT13-1/1FCC Notifications to UserJohn Deere Field Connect™This device complies with part 15 of the FCC Rules.Operat

Page 24 - EC Declaration of Conformity

SpecificationsBA31779,000036D -19-06AUG13-1/1EC Declaration of ConformityDXCE01 —UN—28APR09Deere & CompanyMoline, Illinois USAThe undersigned here

Page 25

Manual Firmware UpdateCZ76372,000072B -19-20OCT14-1/1Manual Firmware UpdateFirmware Update FilesTo locate latest version of John Deere Field Connect™g

Page 26

Viewing Environmental Sensor DataRM72004,00001E9 -19-29OCT13-1/1View Environmental Sensor DataNOTE: On Field Connect™ website, assign environmentalsen

Page 27

AIRMAR WeatherStation 150WX Weather SensorRM72004,0000171 -19-07MAY13-1/1CZ76372,000072E -19-20OCT14-1/1Theory of OperationThe AIRMAR WeatherStation 1

Page 28

AIRMAR WeatherStation 150WX Weather SensorCZ76372,000072C -19-17OCT14-1/1RM72004,0000156 -19-07MAY13-1/1RM72004,000019D -19-07MAY13-1/1CZ76372,000072F

Page 29

Campbell Scientific Model 107–L Temperature ProbeRM72004,0000157 -19-07MAY13-1/1CZ76372,000072D -19-17OCT14-1/1RM72004,00001E8 -19-29OCT13-1/1Theory o

Page 30

Campbell Scientific Model 107–L Temperature ProbeRM72004,00001E7 -19-08OCT13-1/1RM72004,000019E -19-07MAY13-1/1RM72004,000016C -19-07MAY13-1/1Maintena

Page 31 - Manual Firmware Update

Campbell Scientific CS300-L PyranometerRM72004,000015A -19-07MAY13-1/1RM72004,000017C -19-07MAY13-1/1RM72004,000015B -19-07MAY13-1/1RM72004,000015C -1

Page 32

Campbell Scientific CS300-L PyranometerRM72004,000015D -19-07MAY13-1/1TroubleshootingNOTE: If troubleshooting indicates sensor damage,contact your Joh

Page 33 - Theory of Operation

Campbell Scientific LWS-L Leaf Wetness SensorRM72004,000015E -19-07MAY13-1/1RM72004,0000168 -19-07MAY13-1/1RM72004,000015F -19-07MAY13-1/1RM72004,0000

Page 34

IntroductionContinued on next page BA31779,00006FD -19-28OCT13-1/2Industry Canada Notifications to UserPC17927 —UN—29OCT13102914PN=4

Page 35 - Mount Location

Campbell Scientific LWS-L Leaf Wetness SensorRM72004,0000161 -19-07MAY13-1/1TroubleshootingNOTE: If troubleshooting indicates sensor damage,contact yo

Page 36 - Troubleshooting

Campbell Scientific TE525-L Tipping Bucket Rain GaugeRM72004,0000162 -19-07MAY13-1/1RM72004,0000166 -19-07MAY13-1/1RM72004,0000163 -19-29OCT13-1/1RM72

Page 37

Campbell Scientific TE525-L Tipping Bucket Rain GaugeRM72004,0000165 -19-07MAY13-1/1TroubleshootingNOTE: If troubleshooting indicates sensor damage,co

Page 38

End of Year Best PracticesBA31779,0000360 -19-29OCT13-1/1BA31779,0000358 -19-29OCT13-1/1WebsiteNOTE: Deactivate management zone associated withgateway

Page 39

End of Year Best PracticesBA31779,000035E -19-14OCT13-1/1BA31779,000036C -19-29OCT13-1/1StorageAfter removing gateway, soil moisture probe,environment

Page 40

IndexPageAAntennaCellular/GPS Antenna... 15-1Satellite Antenna...

Page 41

IndexPageTemperature Probe ... 50-1Weather Sensor ...

Page 42

John Deere Service Literature AvailableDX,SERVLIT -19-31JUL03-1/1Technical InformationTechnical information can be purchased from John Deere.Some of t

Page 43 - End of Year Best Practices

John Deere Service Literature AvailableSERVLIT-2102914PN=48

Page 44 - Archive and Data Management

John Deere Service Keeps You On The JobDX,IBC,2 -19-02APR02-1/1John Deere Is At Your ServiceCUSTOMER SATISFACTION is important to John Deere.Our deale

Page 45 - Continued on next page

IntroductionBA31779,00006FD -19-28OCT13-2/2PC17928 —UN—28OCT13102914PN=5

Page 46

John Deere Service Keeps You On The JobIBC-2102914PN=50

Page 47 - SERVLIT-1

John Deere Service Keeps You On The JobIBC-3102914PN=51

Page 48 - SERVLIT-2

John Deere Service Keeps You On The JobIBC-4102914PN=52

Page 50

ContentsPageSafetyRecognize Safety Information ...05-1Understand Signal Words...05-1Follow Sa

Page 51

ContentsPageMount Location.....65-1Maintenance.....65-

Page 52

SafetyDX,ALERT -19-29SEP98-1/1DX,SIGNAL -19-03MAR93-1/1DX,READ -19-16JUN09-1/1Recognize Safety InformationThis is a safety-alert symbol. When you see

Commentaires sur ces manuels

Pas de commentaire