2.1.2 Temperature and Relative Humidity
Sensors should be located over an open level area at least 9 m (EPA) in
diameter. The surface should be covered by short grass, or where grass
does not grow, the natural earth surface. Sensors should be located at a
distance of at least four times the height of any nearby obstruction and at
least 30 m (EPA) from large paved areas. Sensors should be protected
from thermal radiation, and adequately ventilated.
Situations to avoid include:
Large industrial heat sources
Rooftops
Steep slopes
Sheltered hollows
High vegetation
H
10H
10T
Height of tree (T)