9522B Iridium Satellite Modem and COM9522B Interface Modem
5.1.3 Step 3: Generic Modem Configuration
Select the Generic element as in FIGURE 5-3. Ensure that the
Communications Enabled box is checked, change the Maximum Baud Rate
to 19200 (9600 for a CR10X), set the Extra Response Time to 3 seconds,
change the Maximum Packet Size to 1000, and set the Delay Hangup to 200
ms. It is recommended that you set a Maximum Time On-Line as part of
your configuration.
Once complete, move to Step 4 to finish the configuration of the Generic
element.
FIGURE 5-3. Generic Hardware Configuration