Campbell COM9522B Guide de l'utilisateur Page 1

Naviguer en ligne ou télécharger Guide de l'utilisateur pour Mise en réseau Campbell COM9522B. Campbell COM9522B User guide Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 46
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
9522B & COM9522B
Iridium Data Modem
Issued: 16.7.13
Copyright © 2009-2012 Campbell Scientific (Canada) Corp.
Printed under licence by Campbell Scientific Ltd
CSL 1003
USER GUIDE
Vue de la page 0
1 2 3 4 5 6 ... 45 46

Résumé du contenu

Page 1 - USER GUIDE

9522B & COM9522B Iridium Data Modem Issued: 16.7.13 Copyright © 2009-2012 Campbell Scientific (Canada) Corp. Pr

Page 3 - Guarantee

1 9522B & COM9522B Iridium Data Modem 1. Overview 1.1 General Description and Modes of Operation The Iridium satellite network consists of a c

Page 4

9522B & COM9522B Iridium Data Modem 2 Table 1. Equipment List for Base and Remote Stations Base Station Remote Station 9522B L-Band Data Mo

Page 5 - PLEASE READ FIRST

User Guide 3 Table 3. Base Station COM9522B Wiring Hardware ComPort Description Colour Connection 9522B Antenna “ANT” SMA connector to antenna c

Page 6

9522B & COM9522B Iridium Data Modem 4 Figure 3. 9522B Remote Station CS I/O Configuration 1.5 Where it works Unlike other satellite systems

Page 7 - Contents

User Guide 5 Mechanical Length: 162 mm Width: 81 mm Depth: 28 mm Weight: 420 g (approximate) 2.2 COM9522B Specifications Power Supply Operati

Page 8

9522B & COM9522B Iridium Data Modem 6 3.2.2 Step 2: Start Hyperterminal Open a new session of Hyperterminal from the Start Menu under: Start, All

Page 9

User Guide 7 Figure 6. Hyperterminal ComPort Connection 3.2.4 Step 4: Hyperterminal Port Settings As in Figure 7 this screen allows you to selec

Page 10

9522B & COM9522B Iridium Data Modem 8 3.2.5 Step 5: Configuring Port Settings Select 19200 bits per second (Baud rate) if you are using a modem

Page 11 - 1. Overview

User Guide 9 Figure 9. Hyperterminal Screen Type the following command string that correlates to the datalogger and/or Baud rate being used: CR100

Page 13 - 1.4 Control

9522B & COM9522B Iridium Data Modem 10 Figure 11. Modem Reply to Command String To ensure that the settings have been stored in the modem type t

Page 14 - 2. Specifications

User Guide 11 4. Datalogger Configuration To ensure proper communications with the datalogger it will be necessary to configure the datalogger. T

Page 15 - 3.2 Setup of Iridium Modems

9522B & COM9522B Iridium Data Modem 12 Figure 14. ComPorts Settings Tab 5. LoggerNet Configuration 5.1 Setup of Loggernet Communications This

Page 16

User Guide 13 Figure 15. LoggerNet Setup Tree 5.1.2 Step 2: ComPort Configuration With the Setup tree entered, you will now need to complete the

Page 17

9522B & COM9522B Iridium Data Modem 14 Figure 16. ComPort Configuration 5.1.3 Step 3: Generic Modem Configuration Select the Generic element as

Page 18

User Guide 15 Figure 17: Generic - Hardware Configuration 5.1.4 Step 4: Generic Modem Configuration Continued Click on the Modem tab located next

Page 19

9522B & COM9522B Iridium Data Modem 16 Figure 18. Generic - Modem Configuration 5.1.5 Step 5: PakBusPort Configuration As in Figure 19, be sure

Page 20

User Guide 17 Figure 19. PakBus Port Configuration 5.1.6 Step 6: CR1000 Configuration Be sure that the Communications Enabled box is checked and

Page 21 - 4. Datalogger Configuration

9522B & COM9522B Iridium Data Modem 18 Figure 20. CR1000 Hardware Configuration Figure 21. CR1000 Schedule Configuration

Page 22 - 5. LoggerNet Configuration

User Guide 19 6. Remote Modem Configuration As a matter of system redundancy it is recommended that the following programming be used as part of y

Page 23

Guarantee This equipment is guaranteed against defects in materials and workmanship. This guarantee applies for twelve months from date of delivery.

Page 24

9522B & COM9522B Iridium Data Modem 20 'sent to the modem allow another 4 minutes to ensure the modem is registered on 'the netw

Page 25

User Guide 21 Scan (5,Sec,3,0) 'Activate Iridium Modems at Noon & Midnight Daily for 15 minutes each time. 'Allow modem w

Page 26

9522B & COM9522B Iridium Data Modem 22 there are no obstructions to the antennas when installing. You may need to reposition or elevate your anten

Page 27

A-1 Appendix A. Sample Data Transfer Calculations The calculations below are based upon maximum theoretical throughputs. Real world transmission

Page 28

Appendix A. Sample Data Transfer Calculations A-2 Power Calculation When configuring a power supply (i.e. solar panel and battery) for a remote stati

Page 29 - 6.1 Program Example 1

B-1 Appendix B. Hardware Installation The hardware shown in this Appendix consists only of hardware listed in Table 1. Although it may be possible t

Page 30 - 6.2 Program Example 2

Appendix B. Hardware Installation B-2 Figure 24. Installed SIM Card B.2 Antenna Installation These instructions apply to both the Base and Remote s

Page 31

Appendix B. Hardware Installation B-3 Figure 26. Antenna and Cable Connected Figure 27. Antenna Attached to Mount With the antenna attached to the

Page 32

Appendix B. Hardware Installation B-4 B.3 9522B Modem Installation The Base station installation should be conducted before proceeding to the field t

Page 33 - Calculations

C-1 Appendix C. Unlocking a SIM Card There are two methods to unlock a SIM Card, and the equipment you have available will dictate which method is u

Page 35 - B.1 SIM Card Installation

Appendix C. Unlocking a SIM Card C-2 The modem should response with an “OK” which means the PIN code has been accepted. This explanation assumes that

Page 36 - B.2 Antenna Installation

D-1 Appendix D. Interfacing Loggernet to RUDICS D.1 Base Station System Requirements: 1. Loggernet Software version 4.0 or greater 2. Telnet comp

Page 37

Appendix D. Interfacing Loggernet to RUDICS D-2 Figure 29. Serial Port Redirector Setup Next click on the Advanced button, and on the Protocol tab s

Page 38

Appendix D. Interfacing Loggernet to RUDICS D-3 Figure 31. Serial Port Redirector Setup (cont’d) D.4 Loggernet Setup Now that the serial port emul

Page 39 - C.1 Handset Method

Appendix D. Interfacing Loggernet to RUDICS D-4 D.4.2 Step 2: Generic Modem Configuration Add a new Generic Modem to the ComPort, select a Maximum B

Page 40

Appendix D. Interfacing Loggernet to RUDICS D-5 Figure 34: Generic Modem Configuration (cont’d) Finally add a PakBusPort Device and a logger and co

Page 41 - D.3 Serial Port Redirector

CAMPBELL SCIENTIFIC COMPANIES Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Page 42

PLEASE READ FIRST About this manual Please note that this manual was originally produced by Campbell Scientific Inc. primarily for the North American

Page 44

i Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab for links to spe

Page 45

ii Appendix A. Sample Data Transfer Calculations... A-1 B. Hardware Installation ....

Page 46

iii 20. CR1000 Hardware Configuration ............... 18 21. CR1000 Schedule Configuration ....

Commentaires sur ces manuels

Pas de commentaire