8
A.1.4 Control Ports
Configuration: 4 digital I/O ports
Input/output resistance: 100kΩ/330Ω, respectively
Input “high” level: 3.8 V to 5.3 V
Input “low” level: -0.3 V to 1.2 V
Output “high” level: 5 V ±0.1 V
Output “low” level: <0.1 V
A.1.5 Model 8032 Multiplexer (See the Appendix F complete specifications)
A.1.6 AVW200 Vibrating Wire Interface (See AVW200 Manual for complete
specifications)
Power requirements: 9.6-16 VDC
Vibrating Wire measurement current: 25 mA
Quiescent current: .3 mA
APPENDIX B - SHIP LIST
B.1 Hardware
The following equipment is included with the system:
• External Power cable
• DB-9 to 10 pin Bendix RS-232 Cable
• USB to RS-232 Adapter
• Small regular screwdriver
• Spare slo-blo fuses (5), 2 amp
• AC Adaptor (110 VAC or 220 VAC)
The following manuals are included:
• MICRO-800 Instruction Manual
• Campbell Scientific Resource disk
Optional accessories:
• COM220 Landline Phone Modem with manual (access Datalogger via phone line)
• Cellular Phone Modem with manual
• Short Haul Modems with manual (current loop communication device)
• MD485 RS-485 Multidrop Interface with manual (Datalogger networking)
• Solar Panel with mounting hardware, charger, and manuals
• RF Modem with manuals (wireless Datalogger communication)
Consult the factory for additional information on any of the optional accessories.