Using Campbell AVW2xx Vibrating Wire Interfaces – MultiLogger Application Note #21 – Page 8 of 13
Wired Configuration – AVW200 with Multiplexers Controlled by MCU (4-10 multiplexers)
The following configuration depicts an AVW200 connected directly to the CR800 or CR1000, with gages
connected to multiplexers controlled by the CR800 or CR1000. Up to 4 multiplexers can be controlled
when using the CR800, up to 10 (up to 12 can be controlled but MultiLogger is limited to 10) when using
the CR1000.
See the tables on the following page for the 4, 6, 8 and 10 multiplexer connection/configuration tables.
1V-
1T+
1T-
GND
2V+
2V-
2T+
2T-
GND
G
C1 (SDI12)
C2 (CLK)
C3 (RES)
G
G
12V
C7 (CR100
G
12V
vary by manufacturer.
RED
BARE
BLACK
WHITE
GREEN
VW#1
COM Hi Odd
COM Lo Odd
COM Hi Even
COM Lo Even
Shield
ENABLE
CLOCK
C8 (CR1000)
C2
C1
RED
BARE
BLACK
WHITE
GREEN
VW#nn
COM Hi Odd
COM Lo Odd
COM Hi Even
COM Lo Even
Shield
ENABLE
CLOCK
RED
BARE
BLACK
WHITE
GREEN
VW#nn
RED
BARE
BLACK
WHITE
GREEN
VW#1
RED
BARE
BLACK
WHITE
GREEN
VW#1
COM Hi Odd
COM Lo Odd
COM Hi Even
COM Lo Even
Shield
ENABLE
CLOCK
RED
BARE
BLACK
WHITE
GREEN
VW#nn
COM Hi Odd
COM Lo Odd
COM Hi Even
COM Lo Even
Shield
ENABLE
CLOCK
RED
BARE
BLACK
WHITE
GREEN
VW#nn
RED
BARE
BLACK
WHITE
GREEN
VW#1
following page for
Control Port
connections for 6, 8 and
10 multiplexers.