CR200-Series
1
Dataloggers / Wireless Sensors
1
e CR206, CR211, and CR216 dataloggers replaced the CR205, CR210, and CR215 dataloggers on September 15, 2005.  e newer dataloggers
re ect changes incorporated in the RF401, RF411, and RF416 Spread Spectrum Radios, which replaced the RF400, RF410, and RF415 radios in
May 2005.  e newer dataloggers can be con gured to be used in systems that contain the retired dataloggers and retired radios.
2
Campbell Scienti c is increasing the  nal storage memory from 128 kbytes to 512 kbytes. Dataloggers with the increased memory have 512k on
their label.
Features
Campbell Scienti cs smallest, lowest cost datalogger
Optimal for measuring one or two simple sensors
512 kbytes of Flash  nal storage memory; approxi-
mately 128,000 data points
2
Fastest scan rate of once per second
12-bit analog to digital conversions
Gas Discharge Tube (GDT) protected inputs
Data values stored in tables with a time stamp and
record number
Battery-backed SRAM and clock that ensure data,
programs, and accurate time are maintained while
a CR200-series datalogger is disconnected from
the main power source
PakBus® communication protocol used, which is a
simpli ed variation of Internet protocols.
Input/Output Channels
Gas discharge tubes provide rugged electrostatic
discharge protection for the inputs. The CR200-
series loggers have five single-ended analog inputs,
one switch closure pulse input, one low level ac
pulse input, two control ports, two excitation chan-
nels (2.5 or 5 V), and one switched battery output.
One of the control ports can be used as an SDI-12
port. Input voltage range is 0 to +2500 mV with
0.6 mV resolution. Please note that differential
measurements are not supported.
Program/Data Storage
Programs and data are stored in a non-volatile Flash
memory. Final storage has 512 kbytes of memory that
provides approximately 128,000 data points in the
table-based memory structure.
{
Antenna Connector:
Connects to a whip
antenna or an antenna
cable (CR206, CR211,
and CR216 only).
Input/Output
Connections:
Measure, commu-
nicate with, and
power sensors.
LEDs: Indicate
datalogger is scan-
ning, transmitting,
or receiving.
RS-232 Port: Supports
communications with a com-
puter. The CR295 has a second
serial port dedicated for satel-
lite communications.
Vue de la page 1