Appendix C. Configuring the Raven for PPP
Datalogger Settings:
Using the Device Configuration Utility, configure the following setting on the
TCP/IP tab:
Config Port Used = RS232
IP Address = 0.0.0.0
Modem Dial String = PPP
Modem Dial Response = CONNECT
User Name and Password are blank
Using the Device Configuration Utility, select the “Net Services” tab. The
“PakBus/TCP Service Port” default is 6785. This is the “Port” number that
will follow the “IP address” for LoggerNet to communicate with the
datalogger.