Number 4250-2010
Revision 0.1
Date MAY 1996
Page 15 of 37
VERIFY Verify that the GOES primary channel select switches are set to
GOES “900” and the secondary channel select switches set to "000." If the
SWITCHES switches are not set to these channels, they must be reset prior to
continuing with servicing of the DCP.
CLEAN Spray the contacts on all external (front panel) connectors with
EXTERNAL contact cleaner.
CONTACTS
CHECK Check the mounting screws for all front panel connectors. Loose
MOUNTING screws should be tightened.
SCREWS
REPLACE If the battery is more than five (5) years old (as indicated by the
BATTERY installation date marked on the battery), or if the battery failed the
battery test during inspection, the battery must be replaced. Battery
replacement procedures are as follows:
Turn the power switch OFF.
Disconnect any external power source (battery or battery charger)
from the DCP.
Disconnect the DCP internal battery connectors.
Remove the circuit board hold-down bracket.
Remove the battery hold-down bracket.
Lift the battery out of the DCP case.
With a permanent marker, write the installation date on the new
battery.
Place the new battery in the DCP case.
Replace the battery hold-down bracket.
CLEAN Check the power switch. If it is not "OFF," turn it OFF.
CIRCUIT
BOARD Remove the DCP plug-in circuit boards.
Clean printed circuit board's edge connector contacts and the ribbon
cable connector contacts with contact cleaner.
CLEAN Clean the backplane connectors with contact cleaner.
BACKPLANE
CONNECTORS Clean the contacts on the ribbon cable connectors with contact
cleaner.