CS475, CS476, and CS477 Radar Water Level Sensor
8
5. Choose the outputs and then select Finish.
6. Wire according to the wiring diagram generated by Short Cut.
5. Overview
The CS475, CS476, and CS477 emit short microwave pulses and measure the
elapsed time between the emission and return of the pulses. The elapsed time
measurement is used to calculate the distance between the sensor face and the target
(for example, water, grain, slurry). The distance value can be used to determine
depth.
These radar sensors output a digital SDI-12 signal to indicate distance and stage.
This output is acceptable for recording devices with SDI-12 capability including
Campbell Scientific dataloggers.