Campbell CM375 Manuel d'instructions Page 22

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 30
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 21
CM375 Portable 10-Meter Mast
Always maintain a safe distance between the mast and
any overhead power lines. Contact local utilities prior
to assembling the mast to locate any buried utility lines
in the area the mast is to be installed.
FIGURE 3-21. 19282 duckbill anchor and cable assembly (left). The
25699 has a threaded rod instead of the cable. The drive rod (right)
is used for both the 19282 and 25699.
FIGURE 3-22. Anchor driven into ground at 45° angle
WARNING
45°
Anchor
Rod
Anchor
Cable
14
Vue de la page 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 28 29 30

Commentaires sur ces manuels

Pas de commentaire