Power Supply
4.2.2 Installing/Changing the Battery
The PS12-LA power supply housing forms the battery holder. It is shown on figure 12, together with other elements
of the power supply.
Follow the below specified guidelines to replace the battery:
• DetachthecoverofthePS12-LAhousingbyunscrewingthetwoscrewonbothsidesofthecap;
• DisconnectpowertothedataloggerbytogglingtheswitchtoOFF;
• ClipoffthebatteryconnectorfromtheterminalINT;
• Takeoutthebattery;
• Putinthenewbattery,makesurethebatteryterminalsareonthesideoftheregulator;
• PlugthebatteryconnectorintotheINTterminal,makesuretheclipisproperlyattached;
• ReconnectpowertothedataloggerbytogglingtheswitchtoON;
• Replacethecover.
Figure 12: PS12-LA Power Supply for CR10X Storage and Control Module
INT Battery Terminal
Charging Indicator
ON/OFF Switch
Input Terminals Solar
Power Supply
12V Terminals to CR10X
Battery Connected to PS12LA Regulator
Rechargeable Battery
PS12LA Housing