Structure Diagram (continuation 2)
OUTPUT
inp 22 CREATE SIGNA TURE “SIGN1440”
inp 23 MEASURE BATT_VOLT “battery voltage”
SET ARRAY_ID = 100
OUTPUT
ARRAY_ID
STN -ID
YEAR
DAY
AVG(AIR_TEMP)
AVG(VP)
AVG(VPD)
MAX (AIR_TEMP)
MIN (AIR_TEMP)
SUM (RAIN)
SAMPLE(OD_SOLAR)
“cum. one day solar rad. In [MJ/M2]”
WIND VECTOR
- scalar mean horizontal wind speed [m/s]
- unit vector mean direction [degrees]
- standard deviation of direction [degrees]
SAMPLE(SIGN1440)
SAMPLE(BATT_VOLT)
“after output all values are automatically set to zero”
SET OD_SOLAR = 0 “new day => day. cum. value = 0”
END