Appendix E. CR510PB w/ P190s to CR205s Network
E-7
4. Configure a CR510PB PakBus address of “100” like this inEdlog’s
Options\Pakbus Settings:
FIGURE E-2. P190 Edlog PakBus Settings
Configuring the maximum nodes, maximum neighbors, and maximum
routers allows the CR510PB to function as a router in the network.
Notice that “Network” is the only setup group unchecked. There is no need
of Neighbor Filter or Beacon setup because the P190 instruction creates a
static route to each CR205 in the swath.
5. Save the program as P190TRANSFER.dld and compile it.
6. Send the program to the CR510PB.
7. Configure a Numeric Display in Connect Screen showing the CR510PB’s
Input Locations to monitor the remote CR205s’ 109-Ls (or simulated 109-
Ls). It can look something like this: